For over 40 years, Kavlico
has led the way when it comes to Control Position
Feedback Sensors for power generation turbines.
Typical baseline installation includes valves, actuators,
and stator guide vane systems for both gas and steam
turbine systems. |
| |
 |
|
LVDTs for gas turbine
systems are generally externally mounted
designs, either block
or bulkhead mounted and
usually single or dual feedback A
devices. The 4-wire designs have a
37-degree lead angle fitting per SAE
standard AS4395G06 as
an exit closure for the wire conduit.
The various designs
include all stainless steel sealed
housings that add to the robust quality
of the devices, for use in Zone 2,
Hazardous areas.
Specific production
designs are currently certified to
the following specification levels:
- Factory
Mutual approved for Intrinsically
Safe, Non-Incendive applications.
- IEC-CENELEC
approved for Non-Incendive, Ex N
IIC T3 applications.
- IEC-CENELEC
approved Non-Incendive, Ex N IIC
T3,
ETL Certified to CAN/CSA C22.2 No.
213,
ETL Certified to UL Standard 1604.
ATEX Compliant:
Equipment Group II, Category 3 for
use in Zone 2 applications.
Typical Performance
Parameters:
-
Excitation Voltage: 7.0 VRMS
- Excitation
Frequency: 3000 Hz
- Electric
Stroke: 0.5" to 11.0"
- Wave
Form: Sine
- Power
Apparent: 1.0 VA Max.
- Load:
10K Ohms
- Linearity:
±1.0%
- Temperature
Range: -100°F to +350°F
- Signal
Output: +0.7 VRMS to 3.5 VRMS
Data Sheet /
LVDT
/
Note: Voltage range
is constant for any stroke.
Only the sensitivity changes (v/V/Inch)
|
|

/
View
Larger Image / |
|
|
| |
 |
|
In addition to
LVDTs, Kavlico also supplies Rotary
Variable Differential Transformers
(RVDTs) in both single and dual tandem
configurations for power plant use.
This design
group has been certified for:
- North
America: Class I, Division 2, Groups
A-D
- Europe:
Eex nV II T3, SIRA 99Y4045X
- ETL
Certified to CAN/CSA C22.2 No. 213
- ETL
Certified to UL Standard 1604
Data Sheet /
RVDT
/
These RVDTs can
be upgraded to an Intrinsically Safe
level by use of a Barrier Circuit
Interface between the sensor and the
power Source.
Caution Note: It
is the responsibility of the system
installer to review the need for any
intrinsic safety barrier to limit
the transfer of energy between the
interface equipment and the RVDTs
and LVDTs.
|
|

/
View
Larger Image /
|
|
|
| |
 |
|
Feedback control
sensors for steam turbine applications
utilize a slightly different winding
design, using on 3-wires and are described
as Variable AC Impedance sensors.
These devices have a 1/8-14 NPT fitting
as an exit closure for the wire conduit
or a PT-02H-14-5P type connector and
can either be blocked
or bulkhead mounted.
The various designs
include all stainless steel sealed
housings that add to the robust design
of the overall device. When used with
a Kavlico Carrier Demodulator, P/N
GM 6244, specific designs can be considered
as having a power and current limiting
device per NEC Class 2.
Many production
designs are currently certified to
the following specification levels:
- UL
Listed (219Y)
- Telemetering
Equipment for Hazardous Locations,
- Class
I, groups B, C, and D.
Typical Performance
Parameters:
-
Excitation Voltage: 3.0 VRMS
to 24VRMS
- Excitation
Frequency: 60 Hz to 3000 Hz
- Electrical
Stroke: +0.75" to +26.0"
- Linearity:
±0.2% Full Stroke / ±1.5%
@ 110% Full Stroke
- Temperature
Range: -100°F to +300°F
Data Sheet /
LVDT
/
|
|

/
View